Application Unit

40/1000 Sinus Facade Trapeze

40/1000 sinus façade trapeze is among the most popular products of the construction industry. 40/1000 sinus façade trapeze used for covering roofs with high slopes and areas with wide purlin spacing; It stands out because it can also serve aesthetic purposes. 40/1000 sinus façade trapeze is frequently preferred due to its ease of use.

Unprocessed Sheet Width 1.200 Mm
Useful Covering Width 990 Mm
Number of Ridges
Ridge Height 40 Mm
Ridge Width 165 Mm
Sheet Thickness 0,35 – 1,00 Mm
Sheet Type Painted Galvaniz – Galvaniz – Alüminyum
Paint Type Polyester – PVDF – Plastisol

40 / 1000 Formed Trapezoidal Sheet Spread Load Bearing Table (Multi Span Kg/m2)

Sheet Thickness Weight 1,00 Mt 1,25 Mt 1,50 Mt 1,75 Mt 2,00 Mt 2,25 Mt 2,50 Mt 2,80 Mt 3,00 Mt 3,30 Mt
0,50 Mm  4,76 749 521 377 254 210 164 148 113 99 83
0,60 Mm  5,72 879 613 445 300 248 193 174 132 114 95
0,70 Mm 6,67 1.033 721 524 354 293 228 204 153 131 108
0,80 Mm  7,62 1.213 848 617 418 346 269 240 178 151 123
0,90 Mm 8,57 1.425 998 728 493 409 317 281 207 174 141
1,00 Mm 9,53 1.674 1.1744 857 582 483 374 331 240 200 160

Calculations were made in accordance with TS EN 14509.
Self weight, live load, wind load and temperature variation (Δt=20 °C) are taken into account.
The deflection limit of L/200 is used.
Calculations were made by TİCEM Advanced Construction Technologies.
Please consult Eska Metal for transports that are not included in the load chart.