19/168 - 1000
The 19/168–1000 trapezoidal sheet profile consists of 7 ribs in total, featuring a rib height of 19 mm, a spacing of 168 mm between the ribs, and an effective coverage width of 1000 mm.
This profile, which can be manufactured from cold-rolled steel (DKP), pre-painted galvanized steel, galvanized steel, stainless steel, or aluminum, features a high number of ribs with a low rib height; consequently, it is typically preferred for facade cladding and as an under-roofing material in applications where the spacing between purlins is narrow.
Alternative RAL Codes
RAL 1018
RAL 2004
RAL 3009
RAL 3020
RAL 5015
RAL 6029
RAL 7016
RAL 7038
RAL 9002
RAL 9006
RAL 1018
RAL 2004
RAL 3009
RAL 3020
RAL 5015
RAL 6029
RAL 7016
RAL 7038
RAL 9002
RAL 9006
Width of Unprocessed Sheet Metal |
1120 mm |
Effective Coating Width |
1000 mm |
Number of Ribs |
7 Units |
Rib Height |
19 mm |
Width Between Corrugations |
168 mm |
Sheet Thickness |
0,35 - 1,20 mm |
Sheet Type |
Cold-Rolled Steel (DKP) - Pre-painted Galvanized Steel - Galvanized Steel - Aluminum - Stainless Steel |
Paint Type |
Polyester - PVDF - Plastisol |
Load-Bearing Capacity Table for 19/1000 Profile Trapezoidal Metal Sheets (multi-span, kg/m²)
Sheet Thickness | Weight (kg/m²) | 0,75 m | 1,00 m | 1,25 m | 1,50 m | 1,75 m | 2,00 m | 2,25 m | 2,50 m |
|---|---|---|---|---|---|---|---|---|---|
0,40mm |
3,52 |
169 |
155 |
114 |
76 |
- |
- |
- |
- |
0,50 mm |
4,40 |
230 |
208 |
188 |
138 |
102 |
78 |
- |
- |
0,60 mm |
5,28 |
288 |
256 |
228 |
168 |
124 |
95 |
73 |
- |
0,70 mm |
6,16 |
352 |
308 |
270 |
198 |
145 |
111 |
86 |
- |
0,80 mm |
7,04 |
403 |
354 |
311 |
228 |
167 |
128 |
99 |
66 |
0,90 mm |
7,92 |
460 |
401 |
349 |
257 |
189 |
145 |
111 |
75 |
- The calculations have been performed in accordance with TS EN 14509.
- Dead load, live load, wind load, and temperature variation (Δt=20 °C) have been taken into account.
- A deflection limit of L/200 has been applied.
- The calculations were carried out by TİCEM İleri Yapı Teknolojileri.
- Please consult Eska Metal for load-bearing scenarios not included in the load table.